Spiroergometry
The module Spiroergometry is used to document spiroergometry examinations. The cardiopulmonary exercise test analyses the reactions and the interplay of the heart, circulation, breathing and metabolism during gradually increasing exercise, both in terms of qualitative and quantitative measures.
The examinations ought to be performed according to DZHK-SOP-K-07 .
The examinations ought to be performed according to DZHK-SOP-K-07 .
Content
Examination details
Was the cardiopulmonary exercise testing performed
Fieldname: spiro_janein Data type: String with following options yes no unknown not assessed
Date of examination
Fieldname: spiro_date Data type: Timestamp with date, month and year
Quality level
- Level 1: The examination is performed in accordance with the guidelines of the medical associations.
- Level 2: The examination is performed in accordance with the specifications of the DZHK SOP. Minimum requirements to ensure the quality of the implementation and the examiners are defined in the SOP.
- Level 3: The examination is performed in accordance with the specifications of the DZHK SOP and certification of the examiners: Definition of intr-observer and interobserver-variability (standard of epidemiological studies).
DZHK-SOP-K-07: Spiroergonometry, Version: V1.1, Valid as of: 01.07.2015
Fieldname: spiro_qualitaet Data type: Integer with following options 1 2 3
Examination
Pacemaker
Fieldname: spiro_schritt Data type: String with following options yes no unknown not assessed
Herz rate
Fieldname: spiro_rhytm Data type: String with following options sinus rhythm atrial fibrillation pacemaker rhythm unknown not assessed
Use of beta blockers
Fieldname: spiro_beta Data type: String with following options yes no unknown not assessed
Duration of exercise
Fieldname: spiro_belastung Data type: Timestamp with minutes and seconds
Type of exercise
Fieldname: spiro_laufband Note in CRF: Treadmill Data type: String following options Bruce protocol modified Bruce protocol modified Naughton protocol unknown not assessed
Fieldname: spiro_fahrrad Note in CRF: Bicycle Data type: String with following options modified Jones protocol WHO protocol unknown not assessed
Reason for stopping
Objective stopping criteria:Subjective stopping criteria:
- ST depression (> 0.2 mV) or elevation.
- Progressive atrial or ventricular arrhythmia or block images
- Newly occurring atrial fibrillation
- Drop in heart rate during exercise
- Lack of increase or drop in RR across 2 exercise levels
- Drop in O2 uptake (or oxygen pulse) in spite of increasing the load.
- Maximal fatigue (e.g. of the legs)
- Thoracic pain (e.g. symptoms of angina), severe dizziness
- Excessive dyspnoea
- Subject signals to examiner to end the examination.
DZHK-SOP-K-07: Spiroergonometry, Version: V1.1, Valid as of: 01.07.2015
Fieldname: spiro_grund Data type: String with following options maximum exertion reached ST segment depression (> 0.2 mV) or elevation progressive atrial or ventricular arrhythmias or bundle branch block patterns frequency decrease during exercise missing BP increase or BP decrease over 2 exercise levels maximum exhaustion (e.g. of legs) chest pain (e.g. AP symptoms), severe dizziness excessive dyspnoea subject's expression of the wish to terminate the test unknown not assessed
HR (at rest)
Fieldname: spiro_hf_ruhe Data type: Integer with maximum 3 digits in /min
Maximum HR (during exercise)
Fieldname: spiro_hf_belast Data type: Integer with maximum 3 digits in /min
HR (1min after exercise)
Fieldname: spiro_hf_1min Data type: Integer with maximum 3 digits in /min
Systolic BP (at rest)
Fieldname: spiro_rrsys_ruhe Data type: Integer with maximum 3 digits in mmHg
Diastolic BP (at rest)
Fieldname: spiro_rrdia_ruhe Data type: Integer with maximum 3 digits in mmHg
Systolic BP (during exercise)
Fieldname: spiro_rrsys_belast Data type: Integer with maximum 3 digits in mmHg
Diastolic BP (during exercise)
Fieldname: spiro_rrdia_belast Data type: Integer with maximum 3 digits in mmHg
Watt (max)
Fieldname: spiro_watt Data type: Integer with maximum 3 digits in Watt
VE/VCO2 (at rest)
Fieldname: spiro_ve_vco2_ruhe Data type: Floating point number with 3 places before and 1 place after comma
VE/VCO2 (during exercise)
Fieldname: spiro_ve_vco2_belast Data type: Floating point number with 3 places before and 1 place after comma
PET CO2 (at rest)
Fieldname: spiro_pet_vco2_ruhe Data type: Integer with maximum 3 digits in mmHg
PET CO2 (during exercise)
Fieldname: spiro_pet_vco2_belast Data type: Integer with maximum 3 digits in mmHg
VE/VCO2-slope
Defined as the slope of the straight line in field 5 (VE to VCO₂) value one minute after starting the exercise until VT2 (RCP).DZHK-SOP-K-07: Spiroergonometry, Version: V1.1, Valid as of: 01.07.2015
Fieldname: spiro_slope Data type: Integer with maximum 3 digits
VO2 (at rest)
Fieldname: spiro_vo2_ruhe Data type: Floating point number with 3 places before and 3 places after comma
Fieldname: spiro_vo2ruh_einheit Data type: String with following options ml/min l/min
VO2 peak
Highest VO2value achieved during exercise. A reliable statement about VO₂ peak can only be made if an RER of >1.05 was achieved during exercise.DZHK-SOP-K-07: Spiroergonometry, Version: V1.1, Valid as of: 01.07.2015
Fieldname: spiro_vo2_peak Data type: Integer with maximum 4 digits in ml/min
VO2 Norm
Fieldname: spiro_vo2_norm Data type: Floating point number with 4 places before and 3 places after comma
Fieldname: spiro_vo2nor_einheit Data type: String with following options ml/min l/min
VO2 AT
Fieldname: spiro_vo2_at Data type: Floating point number with 4 places before and 3 places after comma
Fieldname: spiro_vo2at_einheit Data type: String with following options ml/min l/min
VE max
Fieldname: spiro_ve_max Data type: Integer with maximum 3 digits in l/min
RR (respiratory rate) (at rest)
Fieldname: spiro_af_ruhe Data type: Integer with maximum 3 digits in /min
RR (during exercise)
Fieldname: spiro_af_belast Data type: Integer with maximum 3 digits in /min
Maximum RR
Fieldname: spiro_af_max Data type: Integer with maximum 3 digits in /min
VT (at rest)
Fieldname: spiro_vt_ruhe Data type: Floating point number with 2 places before and 1 place after comma in ml
VT (during exercise)
Fieldname: spiro_vt_belast Data type: Floating point number with 2 places before and 1 place after comma in ml
VD/VT (at rest)
Fieldname: spiro_vdvt_ruhe Data type: Floating point number with 2 places before and 1 place after comma in %
VD/VT (during exercise)
Fieldname: spiro_vdvt_belast Data type: Floating point number with 2 places before and 1 place after comma in %
Saturation sO2 (at rest)
Fieldname: spiro_o2_ruhe Data type: Integer with maximum 3 digits in %
Saturation sO2 (during exercise)
Fieldname: spiro_o2_belast Data type: Integer with maximum 3 digits in %
Respiratory quotient (RQ) at rest
Fieldname: spiro_rq_ruhe Data type: Floating point number with 1 place before and 2 places after comma
Respiratory quotient (RQ) during exercise
Fieldname: spiro_rq_max Data type: Floating point number with 1 place before and 2 places after comma
Respiratory quotient after end of exercise (RQ maxpost)
Fieldname: spiro_rq_nach_belast Data type: Floating point number with 2 places before and 1 place after comma
BORG scale
It is recommended to preferably use the 6/20 scale for DZHK studies. The variant of the BORG scale to be used has to be stipulated in the study protocol of the respective studies.
Borg Exertion Scale 6 no exertion at all 7 extremely light 8 9 very light 10 11 light 12 13 somewhat hard 14 15 hard (heavy) 16 17 very hard 18 19 extremely hard 20 maximal exertion DZHK-SOP-K-07: Spiroergonometry, Version: V1.1, Valid as of: 01.07.2015
Borg Dyspnoea Scale 0 nothing at all 0,5 very, very slight (just noticeable) 1 very slight 2 slight 3 moderate 4 somewhat severe 5 severe 6 severe to very severe 7 very severe 8 very severe to very, very severe 9 very, very severe (almost maximal) 10 maximal dyspnoea
Used BORG scale
Fieldname: spiro_borg Data type: String with following options Borg rating of perceived exertion scale (6/20) Borg – dyspnoea scale (0/10) unknown not assessed
Borg rating of perceived exertion scale
Fieldname: spiro_borganst Data type: String with following options 6 - no exertion at all 7 - extremely light 8 9 - very light 10 11 - light 12 13 - somewhat hard 14 15 - hard 16 17 - very hard 18 19 - extremely hard 20 - maximal exertion unknown not assessed
Borg-dyspnoea scale
Fieldname: spiro_borgatem Data type: String with following options 0 - no breathing difficulty at all 0.5 - very, very slight (just noticeable) 1 - very slight 2 - slight 3 - moderate 4 - somewhat severe 5 - severe 6 - severe to very severe 7 - very severe 8 - very severe to very, very severe 9 - very, very severe (almost maximal) 10 - maximal breathing difficulty unknown not assessed